top of page
Writer's pictureLMS RS

Harmonic Reduction in grid connected PV system with double tuned filter

Overview of the Grid-Connected PV System

A typical grid-connected PV system consists of several components that work together to convert solar energy into usable electricity. These components include the photovoltaic (PV) panel, boost converter, inverter, and the grid. In this system, the PV panel generates direct current (DC) electricity, which is then boosted by the boost converter to a higher voltage suitable for grid connection. An inverter is used to convert DC to alternating current (AC), which is fed into the grid.

In this specific setup, the system also includes a nonlinear load and a double-tuned filter to address potential power quality issues, such as harmonic distortion, which can arise due to the nature of nonlinear loads.

Maximum Power Point Tracking (MPPT)

The boost converter in the system is controlled using the Maximum Power Point Tracking (MPPT) algorithm, which ensures the PV panel operates at its maximum power point. The MPPT algorithm adjusts the duty cycle of the boost converter based on the PV voltage and current to optimize the energy extraction from the solar panel.

The duty cycle is adjusted dynamically depending on the power and voltage changes, ensuring that the system continuously operates at the most efficient point. The algorithm compares the instantaneous changes in power and voltage to decide whether to increment or decrement the duty cycle. The goal is to extract the maximum available power from the PV system at all times.



Boost Converter and Inverter Control

The boost converter is designed to step up the voltage from the PV panel to a level that can be efficiently fed into the grid. The voltage is maintained at around 319V, with the terminal voltage of the PV panel set at 600V. The converter’s performance is controlled by calculating and adjusting the inductor and capacitor values, which depend on the PV power and input voltage.

The system also includes an inverter, which is essential for converting DC voltage from the boost converter into AC voltage suitable for grid integration. The inverter is controlled using a combination of voltage control and current control loops. The voltage control loop maintains the desired DC link voltage (600V), while the current control loop ensures the appropriate real power is sent to the grid. Both loops work together to ensure the grid receives stable and quality power.

Harmonics and Power Quality Issues

In grid-connected PV systems, nonlinear loads can introduce significant harmonic distortion into the grid. These loads typically include devices like motors, fluorescent lights, and other electronic equipment, which generate distorted current waveforms. As a result, the grid current quality can degrade, leading to harmonic distortion.

Without proper mitigation, harmonic distortion can cause problems such as overheating in electrical components, poor power factor, and malfunctioning of sensitive equipment. It can also impact the total harmonic distortion (THD), which is a key measure of power quality.

Effect of Nonlinear Loads on Power Quality

When nonlinear loads are introduced into the system, the grid current waveform becomes distorted. In the absence of a harmonic mitigation solution, such as a filter, the THD of the grid current can exceed acceptable levels. In this scenario, the grid current THD may rise above 5%, which is typically considered the upper threshold for acceptable power quality in most systems.

The presence of this harmonic distortion affects not only the efficiency of power transfer but also the overall stability of the grid. Harmonics can interfere with the operation of other equipment connected to the grid, leading to a range of potential issues in power distribution and consumption.

Introducing the Double-Tuned Filter for Harmonic Mitigation

To address the harmonic distortion caused by nonlinear loads, a double-tuned filter is integrated into the system. This filter is designed to target and reduce the impact of specific harmonics—particularly the 5th and 7th harmonic frequencies, which are most commonly generated by nonlinear loads.

The double-tuned filter works by selectively filtering out these unwanted harmonics from the grid current, improving the overall waveform. By tuning the filter to the appropriate frequencies, it significantly reduces the THD and restores the sinusoidal shape of the grid current.

Results: Before and After the Double-Tuned Filter

When the system operates without the double-tuned filter, the grid current exhibits substantial distortion due to the presence of the nonlinear load. The THD in this scenario can reach up to 7.87%, which is well above the acceptable threshold for most grid-connected systems.

However, when the double-tuned filter is activated, the harmonic distortion is reduced significantly. The grid current waveform becomes almost sinusoidal, and the THD drops to around 4.57%. This reduction in THD ensures that the system is in compliance with power quality standards, providing stable and efficient power to the grid.

Conclusion: Enhancing Power Quality with Harmonic Filters

The integration of a double-tuned filter into a grid-connected PV system proves to be an effective solution for mitigating the harmful effects of harmonic distortion caused by nonlinear loads. By reducing the THD and improving the quality of the grid current, the filter ensures that the system operates efficiently and complies with power quality standards.

0 views0 comments

Comentarios


bottom of page